Installation: Contact Closure
Page 16 of 20 // email
[email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSM FSE/PSE EFA - Lift System with FSE or PSE Mount & Electric Flap Actuator
Contact Closure
- Use an RJ45 connector in the CCI
socket on the control box to operate
via contact closure
LED 1
LED 2
LED 3
LED 4
LED 5
CONTACT CLOSURE INPUT
NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.
12V SUPPLY - CURRENT LIMITED
W/G W/O
When 12V attached, device will go to Preset.
When 12V removed, device will go IN.
GO
3GROUND GROUND W/OW/G
4 PIN 4 NOT USED BL BL
5 DEVICE LATCH
Short to GROUND (pin 3), device will go to
Preset, remove short device will go IN.
W/BL W/BL LED 4
6 DEVICE STOP
Momentary short to GROUND (pin 3), stops
device in current position.
Momentary short to GROUND (pin 3), makes
device go OUT.
W/BR W/BR LED 2
8 DEVICE IN
Momentary short to GROUND (pin 3), makes
device go IN.
CONTACT CLOSURE
LED INDICATOR