Trouble Shooting:
Page 15 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
ET / ET60 - Electric Tilt Mechanism
ET Electric Tilt Mechanism - Trouble shooting guide
Having problems? - Check the following:
1. Are all the connections correct?
2. Is the mechanism being operated correctly?
If the mechanism does not operate correctly, check the items listed in the table below.
Should the problem persist, there may be a malfunction. If this is the case, disconnect the
mains power immediately and contact your installer
SymptomCause RemedyPage
Emergency stop removed Replace emergency stop 13
Remote control or batteries
faulty
Replace batteries or remote 14
Motor or control box faulty
Apply mains power directly, via AC1
on control box
16
Incorrect pin configuration
Terminate 8-pin RJ45 to 568/b pin
configuration
12
Faulty wiring Replace connector or cable 12
Faulty control box Test contact closure on control box 12
Incorrect settings Refer to instructions 13
Incorrect pin configuration
Terminate 6-pin RJ11 to
configuration supplied
13
ASC11 protocol error Amend Protocol 13
Mechanism not working
Contact closure not working
RS232 not working